If the specific pressure sensor design of the submersible pressure transmitter or level probe is selected to gauge the filling levels, this can indicate that the probe is used under environmental requirements which would cause failure of common level sensors.
The most unfortunate circumstances such as soiled media, abrasive ingredients and sludge when used in wastewater treatment plants, brackish and wastewater tanks and even digester towers, impose special requirements on the look of a submersible pressure transmitter. One of the main requirements on a submersible pressure transmitter would be to obtain the lowest possible susceptibility to contamination or build-up of the pressure sensor by optimizing its design. Because of this , the normal design of a pressure transmitter with narrow pressure ports isn’t used within level probes because it would have a tendency to clog such applications.
The design of the submersible pressure transmitter and its pressurised sensor diaphragm is optimised to experience very low susceptibility to contamination. However, continuous operation in soiled media can lead to sticking of dirt particles on the stainless diaphragm. To get the highest accuracy and fastest response times in case of level change, the thickness of this stainless steel diaphragm has already been minimised ex factory to just a few microns. Therefore, cleaning of the diaphragm must be completed with caution. Always stay away from sharp or edged tools. Additionally it is strongly advised never to use the commonly used screwdrivers or pens.
If cleaning of Outstanding is necessary, then rinse it utilizing a weak water jet or clean it carefully using compressed air. Damage of the diaphragm due to denting or notching, even if it seems to be purely superficial, leads to significant losses in the accuracy of level measurement. Deformation of the diaphragm often shifts the zero point of the pressure measurement in the inner electronic measurement system and also distorts the output signal linearisation which includes been adjusted ex works to the undamaged diaphragm. Thus, the submersible pressure transmitter with damaged diaphragm generates falsified measurement of the existing filling level and, therefore, cannot be considered a trusted measuring instrument any longer. Thus, complete replacement of the damaged instrument is absolutely necessary.
Please find more info with this topic on our information platform ?Hydrostatic level measurement?